Efficiency Nova Scotia Commercial Heating Rebate
The following tables list product requirements and available rebates for a range of energy-efficient commercial heating equipment.
Offered by Efficiency Nova Scotia
Amount
no fixed amount
Quick eligibility check
Who can apply
Integrated Dual Enthalpy Economizer Controls
Product: Integrated Dual Enthalpy Economizer Controls; Requirements: Must be installed on new equipment that is also eligible for rebates; Rebate: $250
HVAC Hotel Occupancy Sensors
Product: With building integrated intelligent control
Requirements: Must control electric heating
Requirements: Maximum of one rebate per room
Requirements: Must set back temperature when space is not occupied
Requirements: Hotel must operate year round
Product: Without building integrated intelligent control
Requirements: Must control electric heating
Requirements: Maximum of one rebate per room
Requirements: Must set back temperature when space is not occupied
Requirements: Hotel must operate year round
Small Air Source Heat Pumps - Installed in Multi-Unit Facilities (3 or more units)
Heat pumps found on the Natural Resources Canada Cold Climate Air Source Heat Pumps in Quebec and Nova Scotia list are considered to meet the product criteria.
Requirements: Applicant must be property owner
Requirements: Property must have three units or more and be electrically heated
Requirements: Heat pump must be utilized over the heating season
Requirements: Systems must be AHRI matched systems
Requirements: Contact us prior to purchase if replacing an existing air-source heat pump or in new construction
Requirements: Applicant must be property owner
Requirements: Property must have three units or more and be electrically heated
Requirements: Heat pump must be utilized over the heating season
Requirements: Systems must be AHRI matched systems
Requirements: Contact us prior to purchase if replacing an existing air-source heat pump or in new construction
Small Air Source Heat Pumps - Installed in Commercial Facilities
Heat pumps found on the Natural Resources Canada Cold Climate Air Source Heat Pumps in Quebec and Nova Scotia list are considered to meet the product criteria.
Requirements: Facility must be commercial property
Requirements: Heat Pump must be utilized over the heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI matched systems
Requirements: Contact us prior to purchase if replacing an existing air-source heat pump or in new construction
Requirements: Facility must be commercial property
Requirements: Heat Pump must be utilized over the heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI matched systems
Requirements: Contact us prior to purchase if replacing an existing air-source heat pump or in new construction
Requirements: Facility must be commercial property
Requirements: Heat Pump must be utilized over the heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI matched systems
Requirements: Contact us prior to purchase if replacing an existing air-source heat pump or in new construction
Requirements: Facility must be commercial property
Requirements: Heat Pump must be utilized over the heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI matched systems
Requirements: Contact us prior to purchase if replacing an existing air-source heat pump or in new construction
Requirements: Facility must be commercial property
Requirements: Heat Pump must be utilized over the heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI matched systems
Requirements: Contact us prior to purchase if replacing an existing air-source heat pump or in new construction
Large Air Source Heat Pumps
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Ground & Water Source Heat Pumps
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Requirements: Contact us if replacing an existing air-source or water source heat pump or in a new construction
Requirements: Tested in accordance to ASHRAE / ANSI / AHRI / ISO standard 13256-1 & 2:2012
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Requirements: Contact us if replacing an existing air-source or water source heat pump or in a new construction
Requirements: Tested in accordance to ASHRAE / ANSI / AHRI / ISO standard 13256-1 & 2:2012
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Requirements: Contact us if replacing an existing air-source or water source heat pump or in a new construction
Requirements: Tested in accordance to ASHRAE / ANSI / AHRI / ISO standard 13256-1 & 2:2012
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Requirements: Contact us if replacing an existing air-source or water source heat pump or in a new construction
Requirements: Tested in accordance to ASHRAE / ANSI / AHRI / ISO standard 13256-1 & 2:2012
Air-to-Water Heat Pumps
Requirements: Heat pump must be utilized during the heating season
Requirements: Must offset electrical resistance heating
Requirements: Products must be CSA approved for use in Canada
Requirements: Other hydronic systems (excluding in-floor radiant) must include additional heat exchangers and/or a heat load calculation confirming the baseline equipment is sufficient at indoor loop operating temp
Requirements: Split units must be designed for use together
Requirements: Minimum 110F Water Supply Temperature
Requirements: Contact us if replacing an existing air-source or water source heat pump or in new construction
Packaged Terminal Heat Pumps (PTHP) - New Construction
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Must be AHRI certified (standard size only)
Requirements: Contact us if replacing an existing PTHP unit or in a new construction
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Must be AHRI certified (standard size only)
Requirements: Contact us if replacing an existing PTHP unit or in a new construction
Packaged Terminal Heat Pumps (PTHP) - Replacement
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Must be AHRI certified (standard size only)
Requirements: Contact us if replacing an existing PTHP unit or in a new construction
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Must be AHRI certified (standard size only)
Requirements: Contact us if replacing an existing PTHP unit or in a new construction
Commercial Electric Thermal Storage (ETS) Systems
Requirements: Must be supplementing electric heat source
Requirements: Contact us if the ETS unit(s) will be installed in a New Construction
Requirements: Must be supplementing electric heat source
Requirements: Contact us if the ETS unit(s) will be installed in a New Construction
Requirements: Must be supplementing electric heat source
Requirements: Contact us if the ETS unit(s) will be installed in a New Construction
About the funding
The following tables list product requirements and available rebates for a range of energy-efficient commercial heating equipment.
Integrated Dual Enthalpy Economizer Controls
Product: Integrated Dual Enthalpy Economizer Controls; Requirements: Must be installed on new equipment that is also eligible for rebates; Rebate: $250
HVAC Hotel Occupancy Sensors
Show all funding details
Product | Requirements | Rebate
Product: With building integrated intelligent control
Requirements: Must control electric heating
Requirements: Maximum of one rebate per room
Requirements: Must set back temperature when space is not occupied
Requirements: Hotel must operate year round
Rebate: $75
Product: Without building integrated intelligent control
Requirements: Must control electric heating
Requirements: Maximum of one rebate per room
Requirements: Must set back temperature when space is not occupied
Requirements: Hotel must operate year round
Rebate: $50
Small Air Source Heat Pumps - Installed in Multi-Unit Facilities (3 or more units)
Heat pumps found on the Natural Resources Canada Cold Climate Air Source Heat Pumps in Quebec and Nova Scotia list are considered to meet the product criteria.
Size (Nominal Capacity) | Type | Min HSPF2 (Region IV) | Min SEER2 | Requirements | Rebate
Size (Nominal Capacity): < 65,000 Btu/h (< 5.4 tons)
Type: Ductless Mini-Split Heat Pump
Min HSPF2 (Region IV): 9
Min SEER2: 17
Requirements: Applicant must be property owner
Requirements: Property must have three units or more and be electrically heated
Requirements: Heat pump must be utilized over the heating season
Requirements: Systems must be AHRI matched systems
Requirements: Contact us prior to purchase if replacing an existing air-source heat pump or in new construction
Rebate: $400 / ton
Size (Nominal Capacity): < 65,000 Btu/h (< 5.4 tons)
Type: Multi-Zone
Min HSPF2 (Region IV): 8.5
Min SEER2: 15
Requirements: Applicant must be property owner
Requirements: Property must have three units or more and be electrically heated
Requirements: Heat pump must be utilized over the heating season
Requirements: Systems must be AHRI matched systems
Requirements: Contact us prior to purchase if replacing an existing air-source heat pump or in new construction
Rebate: $400 / ton
Small Air Source Heat Pumps - Installed in Commercial Facilities
Heat pumps found on the Natural Resources Canada Cold Climate Air Source Heat Pumps in Quebec and Nova Scotia list are considered to meet the product criteria.
Size (Nominal Capacity) | Type | Min HSPF2 (Region IV) | Min SEER2 | Requirements | Rebate
Size (Nominal Capacity): < 65,000 Btu/h (< 5.4 tons)
Type: Single Package Systems
Min HSPF2 (Region IV): 7
Min SEER2: 15
Requirements: Facility must be commercial property
Requirements: Heat Pump must be utilized over the heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI matched systems
Requirements: Contact us prior to purchase if replacing an existing air-source heat pump or in new construction
Rebate: $500 / ton
Size (Nominal Capacity): < 65,000 Btu/h (< 5.4 tons)
Type: Centrally Ducted Split System Heat Pump
Min HSPF2 (Region IV): 8
Min SEER2: 15
Requirements: Facility must be commercial property
Requirements: Heat Pump must be utilized over the heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI matched systems
Requirements: Contact us prior to purchase if replacing an existing air-source heat pump or in new construction
Rebate: $600 / ton
Size (Nominal Capacity): < 65,000 Btu/h (< 5.4 tons)
Type: Ductless Mini-Split Heat Pump
Min HSPF2 (Region IV): 9
Min SEER2: 17
Requirements: Facility must be commercial property
Requirements: Heat Pump must be utilized over the heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI matched systems
Requirements: Contact us prior to purchase if replacing an existing air-source heat pump or in new construction
Rebate: $500 / ton
Size (Nominal Capacity): < 65,000 Btu/h (< 5.4 tons)
Type: Ductless Mini-Split Heat Pump
Min HSPF2 (Region IV): 11
Min SEER2: 22
Requirements: Facility must be commercial property
Requirements: Heat Pump must be utilized over the heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI matched systems
Requirements: Contact us prior to purchase if replacing an existing air-source heat pump or in new construction
Rebate: $600 / ton
Size (Nominal Capacity): < 65,000 Btu/h (< 5.4 tons)
Type: Multi-Zone
Min HSPF2 (Region IV): 8.5
Min SEER2: 15
Requirements: Facility must be commercial property
Requirements: Heat Pump must be utilized over the heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI matched systems
Requirements: Contact us prior to purchase if replacing an existing air-source heat pump or in new construction
Rebate: $400 / ton
Large Air Source Heat Pumps
Size (Nominal Capacity) | High Heating (47F) Min COP | Low Heating (17F) Min COP | Min EER | Requirements | Rebate
Size (Nominal Capacity): ≥ 65,000 Btu/h and < 135,000 Btu/h
High Heating (47F) Min COP: 3.4
Low Heating (17F) Min COP: 2.25
Min EER: 11
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Rebate: $600 / ton
Size (Nominal Capacity): ≥ 65,000 Btu/h and < 135,000 Btu/h
High Heating (47F) Min COP: 3.6
Low Heating (17F) Min COP: 2.45
Min EER: 11.9
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Rebate: $700 / ton
Size (Nominal Capacity): ≥ 135,000 Btu/h and < 240,000 Btu/h
High Heating (47F) Min COP: 3.2
Low Heating (17F) Min COP: 2.05
Min EER: 10.4
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Rebate: $600 / ton
Size (Nominal Capacity): ≥ 135,000 Btu/h and < 240,000 Btu/h
High Heating (47F) Min COP: 3.5
Low Heating (17F) Min COP: 2.25
Min EER: 11.4
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Rebate: $700 / ton
Ground & Water Source Heat Pumps
Size (Nominal Capacity) | Min EER | Min COP | Requirements | Rebate
Size (Nominal Capacity): Open Loop
Min EER: 16.2
Min COP: 3.6
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Requirements: Contact us if replacing an existing air-source or water source heat pump or in a new construction
Requirements: Water loop heat pumps connected to a cooling tower and boiler are not eligible for incentives
Requirements: Tested in accordance to ASHRAE / ANSI / AHRI / ISO standard 13256-1 & 2:2012
Rebate: $500 / ton
Size (Nominal Capacity): Open Loop
Min EER: 20.0
Min COP: 4.0
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Requirements: Contact us if replacing an existing air-source or water source heat pump or in a new construction
Requirements: Water loop heat pumps connected to a cooling tower and boiler are not eligible for incentives
Requirements: Tested in accordance to ASHRAE / ANSI / AHRI / ISO standard 13256-1 & 2:2012
Rebate: $600 / ton
Size (Nominal Capacity): Closed Loop / Direct Geoexchange (DGX)
Min EER: 13.4
Min COP: 3.1
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Requirements: Contact us if replacing an existing air-source or water source heat pump or in a new construction
Requirements: Water loop heat pumps connected to a cooling tower and boiler are not eligible for incentives
Requirements: Tested in accordance to ASHRAE / ANSI / AHRI / ISO standard 13256-1 & 2:2012
Rebate: $500 / ton
Size (Nominal Capacity): Closed Loop / Direct Geoexchange (DGX)
Min EER: 16.0
Min COP: 3.6
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Systems must be AHRI certified matched systems. More information at ahridirectory.org
Requirements: Contact us if replacing an existing air-source or water source heat pump or in a new construction
Requirements: Water loop heat pumps connected to a cooling tower and boiler are not eligible for incentives
Requirements: Tested in accordance to ASHRAE / ANSI / AHRI / ISO standard 13256-1 & 2:2012
Rebate: $600 / ton
Air-to-Water Heat Pumps
Size (Nominal Capacity) | COPH at -15°C | Requirements | Rebate
Size (Nominal Capacity): ≤ 135,000 Btu/h
COPH at -15°C: 1.7
Requirements: Heat pump must be utilized during the heating season
Requirements: Must offset electrical resistance heating
Requirements: Products must be CSA approved for use in Canada
Requirements: Other hydronic systems (excluding in-floor radiant) must include additional heat exchangers and/or a heat load calculation confirming the baseline equipment is sufficient at indoor loop operating temp
Requirements: Split units must be designed for use together
Requirements: Minimum 110F Water Supply Temperature
Requirements: Contact us if replacing an existing air-source or water source heat pump or in new construction
Rebate: $500 / ton
Packaged Terminal Heat Pumps (PTHP) - New Construction
- Standard size refers to having an external wall opening greater than or equal to 16 inches high or greater than or equal to 42 inches wide, and a cross-sectional area greater than or equal to 670 square inches.
** Non-standard size refers to having an external wall opening of less than 16 inches high or less than 42 inches wide, and a cross-sectional area less than 670 square inches.
Size (Nominal Capacity) | High Heating (47F) Min EER | Low Heating (17F) Min COP | Requirements | Rebate,
Size (Nominal Capacity): < 11,000 Btu/h
High Heating (47F) Min EER: 11.0
Low Heating (17F) Min COP: 3.3
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Must be AHRI certified (standard size only)
Requirements: Contact us if replacing an existing PTHP unit or in a new construction
Rebate,: $500 / per unit
Size (Nominal Capacity): ≥ 11,000 Btu/h
High Heating (47F) Min EER: 10.0
Low Heating (17F) Min COP: 2.8
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Must be AHRI certified (standard size only)
Requirements: Contact us if replacing an existing PTHP unit or in a new construction
Rebate,: $500 / per unit
Packaged Terminal Heat Pumps (PTHP) - Replacement
- Standard size refers to having an external wall opening greater than or equal to 16 inches high or greater than or equal to 42 inches wide, and a cross-sectional area greater than or equal to 670 square inches.
** Non-standard size refers to having an external wall opening of less than 16 inches high or less than 42 inches wide, and a cross-sectional area less than 670 square inches.
Size (Nominal Capacity) | Min EER | Min COP | Requirements | Rebate
Size (Nominal Capacity): < 11,000 Btu/h
Min EER: 9.3
Min COP: 2.7
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Must be AHRI certified (standard size only)
Requirements: Contact us if replacing an existing PTHP unit or in a new construction
Rebate: $500 / per unit
Size (Nominal Capacity): ≥ 11,000 Btu/h
Min EER: 7.6
Min COP: 2.5
Requirements: Heat pump must be utilized during heating season
Requirements: Must offset electric resistance heating
Requirements: Must be AHRI certified (standard size only)
Requirements: Contact us if replacing an existing PTHP unit or in a new construction
Rebate: $500 / per unit
Commercial Electric Thermal Storage (ETS) Systems
Product | Requirements | Rebate
Product: Small Commercial ETS: 50 - 150 kWh of Eight-Hour Storage
Requirements: $20 per KWh, lesser of total storage or eight hour storage amount (charging power multiplied by eight)
Requirements: Must be supplementing electric heat source
Requirements: Contact us if the ETS unit(s) will be installed in a New Construction
Rebate: $1,000 / per unit
Product: Medium Commercial ETS: 150 - 300 kWh of Eight-Hour Storage
Requirements: $20 per KWh, lesser of total storage or eight hour storage amount (charging power multiplied by eight)
Requirements: Must be supplementing electric heat source
Requirements: Contact us if the ETS unit(s) will be installed in a New Construction
Rebate: $2,000 / per unit
Product: Large Commercial ETS: 300 kWh and above of Eight-Hour Storage
Requirements: $20 per KWh, lesser of total storage or eight hour storage amount (charging power multiplied by eight)
Requirements: Must be supplementing electric heat source
Requirements: Contact us if the ETS unit(s) will be installed in a New Construction
Rebate: $4,000 / per unit
Similar programs
| Program | Type | Amount | Status |
|---|---|---|---|
| Efficiency Nova Scotia Agriculture Rebate | Rebate | Up to $1,400 in rebates on agricultural technology upgrades, up to $500 on lighting upgrades and up to $2,000 on refrigeration equipment | Open |
| Efficiency Nova Scotia Business Energy Rebate Program: Commercial Solar PV Combination | Rebate | Up to $30,000 | Open |
| Efficiency Nova Scotia Compressed Air Rebate | Rebate | no fixed amount | Open |
| Efficiency Nova Scotia IT & Datacentre Rebate | Rebate | no fixed amount | Open |